How would I go about setting A2 to decend further when trying to pick up a nozzle? It does pick it up, but isn't going deep enough so the nozzle doesn't lock in.
I've previously followed section 6.5 in the manual to setup Nozzle_Y_Exit on all nozzles in the cart, so I think maybe this happens because of the changed Nozzle_Z_Exit.
The meaning of Nozzle_Z_Exit isn't clear to me after reading 6.5 and 6.3: In 6.5, Nozzle_Z_Exit is set for each nozzle to Z=top of part surface of an arbitrary feeder line (same feeder used for all nozzles). 6.3 says "Nozzle Z_Exit is the up position." -->what is that supposed to mean? Also: "In down Z position the nozzle need to be adjusted to the bottom side of the nozzle holder.". --> What's the "down Z position"?
I need to reply in detail later but for the first thing please adjust nozzle height in basic settings for both heads to compensate H1 to H2 Z axis deviation.
Zitat von gj im Beitrag #1Also: "In down Z position the nozzle need to be adjusted to the bottom side of the nozzle holder.". --> What's the "down Z position"?
Nozzle_X_Exit, Nozzle_Y_Exit, Nozzle_Z_Exit need to get adjusted to the center of nozzle changer slot in front position. In down Z position the nozzle need to be adjusted to the bottom side of the nozzle holder. It shouldn’t touch the surface but keep only a very small distance. So, nozzle changer doesn’t get pushed forward by nozzle change cycle.
Please check attached picture
The information was taken from manual chapter 6.3 page 51 |addpics|iq-b-271a.png|/addpics|